Editor’s note: We are in the process of use compressor, mix normally to achieve efficient manufacturing purpose, most moment, the option that we grant lead plane and spare parts and care and maintenance will be a bit morer, and understand and hold what often ignored the condition that waits for respect of a few detail to security however. Notice, the bank of “ a thousand li destroys ” of Yu Yi acupuncture point, look be like is a small issue, if carelessness does not add an attention, not only can create needless waste, can lead to important matter reason one day eventually even. So, go on a long journey in compressor in the process, the problem no matter size, need to try to take seriously solve with fathom, this is the premise that makes sure compressor can hold safe and effective job.

So, we are applying process doubt to be like compressor oil to divide the product that the problem causes to pollute incident to be jumping-off place with an user, the viewpoint that initiates the personage inside course of study is collected and discuss greatly, in an attempt to discusses mutual beneficial purpose in all. This period forum, we come to the intense discussion that what spread out to this listen to netizens.

Participate in extensively, sincerity communication, a lot of difficulty and problem are met be readily solved, this is the force of the network.

The welcome lands forum of industry of Chinese compressor network:

Http://bbs.compressor.cnhttp://bbs.compressor.cn/forum.php? Mod=viewthread&tid=25544&extra

ID: Zhangtianshi

Consult each teacher: I have a client, with compress air to break into pieces with agitate fluorescent material, pneumatics machine, gas tank, cold dry machine, 4 class filter match neat. The fluorescent material after agitate discovering accidentally before long before appears flaxen, changed pipeline, 4 class to filter, was forced a long time, appear again weak yellow, how is this to return a responsibility excuse me? Be basically by what reason cause? Thanked.

ID: Jldzhong

What does fluorescent material encounter to you can become yellow excuse me? The problem that is not compressor probably, must do first clear have other reason.

ID: Zhangtianshi

OK and affirmatory is, the color of the pneumatics engine oil that the client uses formerly is yellow, can be oily cent problem, was the leakage oil that bring about polluted?

ID: White with black

Very possible, the proposal uses the machine that do not have oil, after the system receives oil, do very hard clean after all.

ID: Jysx5127

Is this your client new systematic facility? If be, that asks to enraging a source very tall, the proposal changes cold dry plane into blot machine.

ID: JQLJPL

Still need to think method carries high pressure to shrink airy quality, such should OK solve a problem.

ID: Zhangtianshi

Complement explains, the machine used a year many, after just changing oil for some time afore, become such. Former it is 2 class filter, my proposal instead 4 class, the oil that uses formerly is yellow color, I convert transparent achromatic. All pipeline change stainless steel, undertook cleaning. My method is good only a long time, become former model again. Have friend proposal, want first oil change cent, I had enquired, oil divides what just changed. Consult everybody, how should this do? ? ? Thanked.

ID: Pneumatics machine

It is to cite below the speech of “jysx5127” : Is this your client new systematic facility? If be, that asks to enraging a source very tall, proposal change cold dry plane into blot machine.

My individual feels, this method is feasible, have a try.

ID: Zhangtianshi

But, understand according to me, blot machine just has effect to moisture, do not have the effect to oil, can you go so?

ID: Adsl65362408

What you can be wrapped in gas storage and outfit discharge adds to comparative between cold dry machine is efficient except oil implement accuse oil, changing cold dry machine to be blot machine is to strengthen adsorptive moisture, which influence is knowing namely ah?

ID: Diavyang

It is to cite below “ is white the speech with black ” : Very possible, the proposal is good with the machine that do not have oil, after the system receives oil, do very hard clean after all.

I support this point of view, should so processing is better.

ID: Zhangtianshi

If want to use the machine that do not have oil, that aftertreatment (cold dry machine, filter, gas tank) also want to change?

ID: Diavyang

Not certain also, if do not have oily pollution, need not use actually change.

ID: Leng Huo

This problem looks be like complex, be without be concerned about actually, in the final analysis, affirmation or oil are no good.

ID: Hnfysh

The individual feels, the oil that is you likely very is tasted / the system that answer oil / oily segregator has a problem, microscope and eliminate.

ID: Li321123

I also feel is to compress engine oil to have a problem.

ID: Hyldgzj

Proposal microscope, see pneumatics machine run is oil denied?

ID: Huli

Consider what oil changes to replace above all, if be if, seeing pneumatics machine temperature is normal (with the temperature previously not, change a kind of oil out of order, normal word adds drier of an adsorptive type again with respect to need) , additional, the filter core quality that a few level that you also want to consider you filter has sure.

ID: Tzw200859498

Why do clearing up that fluorescent material first become yellow? Such ability have a definite object in view!

Hydrous much ability increases blot chance, blot machine does not handle oil again. If be oiliness much, the method of get sth done once and for ever changes the plane that do not have oil namely, after all, with respect to the place that you should examine this system now too much.

Run told in oily reason forum many, I repeat below: 1. Check configuration, whether filter treating capacity is insufficient, 2. Oily itself and whether to cheer much, 3. Oily cent and answer vitta, 4. Systematic pressure is low, 5. The aftertreatment has bypass see bypass valve whether leak, 6. Filter itself quality.

ID: Southern mouse

Your conduit filter core filters the area is too small, because velocity of flow is high,cannot filter completely.

ID: [email protected]

The result that answer oil is bad, detached and bad, the oiliness in air is much, best can explaining is which manufacturer, why to plant model, have specific aim so, facilitate communication communication is mixed solve a problem, because each manufacturer are different,type construction is discrepant.

ID: Fujunok

Excuse me, is the machine of your client measured with oil big?

If the requirement to gas is real very tall, then you use the machine that do not have oil only, such meeting provinces play many troubles. Do not have blind faith in filter, its effect did not say well on example.

ID: Leoyong199

The individual thinks, what the oily cent of main empty still press handles is bad (itself quality problem) , because add,install 4 class filter to be no good, the oily content of visible pneumatics machine is too high, the brand pneumatics machine that the proposal has changed.

ID: Wxf

The result that answer oil is bad, detached and bad, oily cent has a problem.

ID: Shilubin

Resemble above those who say, if oily cent is main problem, still have other side especially except oil so, e.g. a vitta position of oily one’s duty, answer vitta whether unobstructed is waited a moment, main reason runs namely oil is serious.

ID: Zhangtianshi

Also did not increase chance of adsorptive type Leng Gan later, it is good to changed plane of a pneumatics. How should be two empty press that can you be before handled? It is the oily component that has traded, still discarded as useless directly?

ID: Zjscq

Must find the problem first, blind changes, do not rise to expect the result, the client can get angry, to moment losing be yourself.

ID: Zhangtianshi

Yes, the thank reminds, I am waiting for the client’s answer.

ID: WDNGCTA

Although repaired a problem to solve with replacement, but encounter such problem, I or proposal consult 3 projects: Exhaust temperature whether on the high side, whether does fuel injection temperature pass low, pressure maintains a powerful person to whether grow (attaint) . Still have, check a machine to tilt? See next oily cent answer vitta, receive paragraph transparent, leave so that moment looks so that see to answer oily quantity.

ID: Yunnan China is complete

What you can be wrapped in gas storage and outfit discharge adds to comparative between cold dry machine is efficient except oil implement accuse oil, changing cold dry machine to be blot machine is to strengthen adsorptive moisture.

ID: Accuse in Fosan

Specific seek an issue, classification again the platoon is checked, our client also has appeared similar problem. Processing technique: Toward the machine by the end that use gas the platoon is checked, we the problem is at that time vitta is answered in 2, there is one to took mesh connect to block a half up before one-way a powerful person.

2022-10-31T05:46:58-07:00October 2022|Categories: Air Compressor Technology|Tags: , |