TL;DR — Direct answer: A forklift manufacturing plant typically runs 7 to 8 bar, 8 to 16 m3/min, on 75 to 132 kW rotary screw compressors, with a 3°C pressure dew point dryer and 0.01 micron filtration protecting chassis welding, mast assembly and load testing from moisture and oil. QiAir, a Chinese screw compressor manufacturer and supplier, sizes systems with clean, stable air so load tests stay trustworthy.

A forklift factory is a heavy steel and hydraulics plant where chassis are welded, masts are assembled, counterweights are fitted, and every finished truck is load-tested before it ships. The line moves slowly compared with appliance plants, but each unit is large, and compressed air touches every step, from the welding bay that builds the chassis to the test yard that proves the lift. Trucks are built in small batches with many variants, so jigs and fixtures change often and the air system must stay steady through every changeover.

Screw compressor installation
Screw compressor installation

The product must lift tonnes safely in a warehouse for years, so a mast assembled with unsteady air or a hydraulic system filled with wet air becomes a safety failure rather than a passing truck. Air quality at the welding, assembly and test stations is therefore a production issue, and buyers who audit the factory will ask about it directly.

Chassis Welding, Cutting and Steel Work

Forklift chassis start as heavy steel plate, cut, bent and welded on lines that use air for clamping, handling and positioning. A chassis that is welded out of square because its fixture shifted will never track straight, and a truck that crabs across a warehouse floor wears its tyres out fast. Stable 7 bar air keeps every chassis true.

Cutting is the most air-hungry job in the steel shop. Plasma and laser cutters use air for cutting and nozzle cleaning, and a pressure sag during a cut leaves a rough edge that needs grinding. Rough edges also slow down welding, because every edge must be ground smooth before the next station can start. Regulate the cutting benches to a steady 7 bar and keep the branch filtered to 0.01 micron.

Steel dust and welding fume drift through the fabrication hall, and dust drawn into the compressor intake scores the airend over time. Duct the intake to clean air outside, fit a heavy-duty pre-filter, and blow out the oil cooler weekly so summer heat does not push discharge temperatures up.

  • Hold 7 bar steady at the chassis welding line
  • Regulate cutting benches to a steady 7 bar
  • Duct the intake away from welding fume and steel dust

Mast Assembly, Hydraulics and Counterweight Fitting

Forklift masts are the most air-sensitive assembly in the plant. Mast channels, chains, rollers and cylinders are fitted with air tools, and a roller set at low pressure can leave a mast that binds when it lifts. Regulate the mast benches to a steady 7 bar and check roller clearance against a standard every week.

Hydraulic work uses air in quieter ways that still matter. Hydraulic lines are flushed and pressure-tested before fitting, and moisture in the flushing air settles into the oil and corrodes valves from the inside. Contaminated oil also shortens pump life, and a failed pump in the field means a truck out of service. Keep the hydraulics branch dried to a 3°C pressure dew point and filtered to 0.01 micron.

Counterweight fitting uses air hoists and handling equipment to move cast iron weights that weigh hundreds of kilograms. A slow hoist stretches the assembly takt time, and a dropped counterweight damages the chassis. Give the fitting area its own receiver and drain it every shift so water never reaches a handling valve.

  • Regulate mast assembly benches to a steady 7 bar
  • Dry hydraulics flushing air to a 3°C dew point
  • Fit a receiver near the counterweight fitting area

Load Testing, Drive Checks and Final Inspection

Load testing is the gate every forklift must pass before shipping. The truck lifts its rated load while engineers check mast stability, tilt and braking, and the air used to drive the test rigs must be stable, because a pressure dip during a lift test can look like a hydraulic fault. Keep the test branch filtered and regulated.

Drive checks run each truck through steering, travel and braking tests, and their air needs are steady rather than spiky. A brake test rig fed on drifting air will give a different result every time, so regulate the test bay to a steady 7 bar and log the header pressure during every session.

Final inspection checks paint, decals and mast alignment, and the air tools used there must not damage a finished truck. A blow-off jet that is too strong can lift a decal edge, and a lifted decal discovered at inspection means rework. Keep the inspection branch filtered and regulated, and fit regulators at each bench.

  • Test with stable, regulated air from a dedicated branch
  • Log header pressure during every load-test session
  • Regulate inspection benches to protect finished paintwork

Buying from China: Sizing Sheet for Forklift Plants

Before requesting a quotation, gather four numbers: the chassis welding and cutting peak flow, the mast and hydraulics assembly air demand, the load-test bay air quality specification, and the distance from the compressor room to the furthest assembly bench. A supplier that quotes from the forklift output alone will miss the welding peak that actually sizes the system.

For most forklift plants the practical range is a 75 to 110 kW variable-speed drive screw compressor at 7.5 or 8 bar, with a refrigerated dryer, 0.01 micron filtration and a 5,000 litre receiver. Larger plants with several assembly lines usually run a duty-plus-standby pair so maintenance never stops a load test.

When comparing Chinese suppliers, ask for the full package price including dryer, filters, receiver and commissioning spares, and confirm the export packing, voltage and documentation for your country. Check the filter element life, the service interval and the availability of filters and airends through the supplier's export channel. QiAir, a Chinese screw compressor manufacturer and supplier, quotes the complete package so buyers compare real installed cost.

  • Collect welding, mast and test loads before quoting
  • Budget 75 to 110 kW VSD plus dryer, filters and receiver
  • Confirm spares, voltage and export packing in writing

Frequently asked questions

What pressure does a forklift plant normally run?

Most run 7 to 8 bar at the header, with welding and cutting at 7 bar, mast benches at 7 bar, and test rigs held at a steady 7 bar.

Why does mast assembly need regulated air?

A roller set at low pressure can leave a mast that binds when it lifts, and a binding mast is a safety issue. Steady air at each bench keeps every roller set correctly.

Should hydraulics flushing share air with welding?

No. Give hydraulics its own dryer and filtration branch, so welding dust and moisture can never reach hydraulic oil and valves.

How much air does a forklift plant use?

Most plants run 8 to 16 m3/min on 75 to 132 kW compressors, with the welding and cutting peaks deciding the size rather than the average assembly load.

Related reading

QiAir is a Chinese manufacturer and supplier of screw air compressors. If you are sourcing a screw compressor from China — for a factory, a food plant, a construction site or a new production line — contact QiAir for a sized quotation, documented performance data and export support.