TL;DR — Direct answer: A heat pump plant needs clean, dry air at 6 to 8 bar for coil fabrication, tube brazing, compressor fitting, refrigerant charging, leak testing and cabinet assembly, with a 3 degree C pressure dew point and 0.01 micron filtration. Size on the coincident peak of the brazing lines and the leak test stations, 5 to 10 cubic metres per minute, roughly a 37 to 75 kW screw compressor. QiAir, a Chinese screw compressor manufacturer and supplier, builds dry-air machines for heat pump plants.
A heat pump moves heat with a refrigeration circuit, and its factory must build that circuit leak-tight enough to hold refrigerant for fifteen years. Copper coils are formed and brazed, compressors and valves are fitted, circuits are evacuated and charged, and every finished unit is leak tested and run through a performance check before packing. Compressed air drives brazing fixtures, tube expanders, leak test rigs, charging stations and assembly tools. QiAir is a Chinese manufacturer and supplier of screw air compressors, and its machines for heat pump plants are specified around clean, dry air first.

The common sizing mistake is counting the assembly lines alone and forgetting brazing and leak testing. Coil lines draw air steadily, brazing stations pulse at every joint, leak test rigs need a long, stable flow for every unit, and cabinet lines use air for sheet metal work and painting. This guide maps where the air goes, explains how to size for brazing and test peaks, sets the dry-air standard that protects coils and refrigerant circuits, and shows what to put on a sizing sheet for a China supplier.
Where Air Is Used: Coils, Brazing, Charging and Leak Testing
Coil fabrication and tube brazing are the heaviest users. Copper tubes are cut, bent and expanded into fins, coils are brazed in fixtures, and headers are fitted, using air for benders, expanders, brazing clamps and part handling, continuously while the lines run. A pressure dip at a tube expander changes the joint tightness, and a loose tube-to-fin joint cuts heat transfer and makes the heat pump noisy in service.
Compressor fitting, refrigerant charging, leak testing, cabinet work and packing take the rest. Compressors are mounted and piped, circuits are evacuated and charged with refrigerant, leak test rigs pressurise each unit and watch for decay, cabinets are cut and painted, and finished units are boxed. Charging air must stay dry, because moisture in a refrigerant circuit forms acid that attacks the compressor from within.
- Coil fabrication and brazing: tube benders, expanders, brazing clamps and part handling running continuously.
- Compressor fitting and charging: mounting, piping, evacuation and refrigerant charging stations.
- Leak testing, cabinets and packing: pressure decay rigs, sheet metal work, painting and boxing.
Sizing for Brazing Lines and Leak Test Stations
List every line and station with its flow at peak and at steady running. A mid-size plant with three to six coil lines, two to four brazing lines and a charging and test area typically peaks at 5 to 10 cubic metres per minute at 6 to 8 bar, roughly a 37 to 75 kW screw compressor, with the peak landing when the brazing lines run at full load while the leak test rigs pressurise together.
Keep the pressure drop to the farthest leak test station under 0.2 bar at peak flow, tighter than general industry, because leak testing measures small pressure changes and a sagging supply gives false readings, and fit a receiver of 500 to 1000 litres per 10 cubic metres per minute to absorb brazing and test spikes. Log pressure at the farthest test station for a week of full production: that log is the honest record of whether the compressor is big enough.
- Size on the coincident peak of the brazing lines and the leak test stations, not on brazing alone.
- Keep far-end pressure drop under 0.2 bar at the leak test stations, with a variable speed drive.
- Log farthest-station pressure during production for a week to prove the sizing in real use.
Dry Air for Coils, Circuits and Refrigerant Integrity
Moisture is the main enemy in heat pump manufacturing. A coil brazed with damp air oxidises inside the joint, moisture in a refrigerant circuit forms acid that attacks the compressor, and damp air in a leak test rig changes the pressure reading and hides a real leak. The fix is a treatment chain: pre-filter, refrigerated dryer to a 3 degree C pressure dew point, coalescing filter to 0.01 micron, and activated-carbon filter for oil vapour, with a final point-of-use filter at each brazing group and test station.
Oil is the second risk: oil in a refrigerant circuit changes the oil balance of the compressor and shortens its life, and oil on a painted cabinet leaves a fisheye in the finish. Keep the compressor room clean, ventilated and cool, drain condensate with automatic zero-loss drains, and test air at the farthest test station quarterly. Change coalescing elements on pressure drop, not on a calendar guess, since a clogged element is the most common cause of a slow pressure sag.
- Fit pre-filter, refrigerated dryer, 0.01 micron coalescing filter and carbon filter, with a final filter at each brazing group and test station.
- Keep the compressor intake away from brazing fume and paint overspray, with a heavy-duty pre-filter checked weekly.
- Drain condensate automatically, and test air at the farthest test station quarterly for oil and moisture.
Buying from China: Sizing Sheet for a Heat Pump Plant Compressor
QiAir is a Chinese manufacturer and supplier of screw air compressors, and a heat pump order should start with a sizing sheet that names the line count. Send the supplier the number of coil lines, brazing lines, charging stations and leak test rigs, the coincident peak at 6 to 8 bar, the air-quality standard the brazing lines and test stations require, ambient temperature and humidity, and the distance to the farthest test station.
Agree the acceptance test before shipment: a full-load run at rated pressure, a dew point reading at the dryer outlet, and an oil-aerosol check at the final filter outlet. On arrival, install on a level plinth with clear cooler airflow, connect drains before the first run, and survey pressure at the farthest test station during the first full production week.
- Send the supplier coil line, brazing line and test rig counts, coincident peak and farthest-station distance.
- Ask for dryer type and filtration grades in writing, and compare oil-free against filtered oil-injected on total cost.
- Accept on a full-load test plus dew point and oil-aerosol checks, then survey pressure at the farthest station in week one.
Frequently asked questions
What pressure does a heat pump plant need?
A heat pump plant needs clean, dry air at 6 to 8 bar for coil fabrication, tube brazing, compressor fitting, refrigerant charging, leak testing and cabinet assembly. Keep far-end pressure drop under 0.2 bar at the leak test stations, because a sagging supply gives false leak readings, and size on the coincident peak of the brazing lines and the leak test stations.
Why must heat pump manufacturing air be dry?
A coil brazed with damp air oxidises inside the joint, moisture in a refrigerant circuit forms acid that attacks the compressor, and damp air in a leak test rig changes the pressure reading and hides a real leak. A pre-filter, refrigerated dryer to a 3 degree C pressure dew point, 0.01 micron coalescing filter and carbon filter in series protect the coils, circuits and test results.
What size screw compressor does a heat pump plant need?
A mid-size heat pump plant with three to six coil lines, two to four brazing lines and a charging and test area typically needs 5 to 10 cubic metres per minute at 6 to 8 bar, roughly a 37 to 75 kW screw compressor with a variable speed drive. Add a 500 to 1000 litre receiver per 10 cubic metres per minute, and verify pressure at the farthest test station under full load.
Related reading
- Screw Compressor Heat Recovery: Turning Waste Heat into Factory Savings
- IoT Monitoring for Screw Compressor Rooms: A China Supplier's Practical Setup
QiAir is a Chinese manufacturer and supplier of screw air compressors. If you are sourcing a screw compressor from China — for a factory, a food plant, a construction site or a new production line — contact QiAir for a sized quotation, documented performance data and export support.