TL;DR — Direct answer: A vacuum cleaner manufacturing plant typically runs 7 to 8 bar, 5 to 12 m3/min, on 37 to 90 kW rotary screw compressors, with a 3°C pressure dew point dryer and 0.01 micron filtration protecting plastic moulding, motor assembly and suction testing from moisture and oil. QiAir, a Chinese screw compressor manufacturer and supplier, sizes systems with clean, stable air so suction tests stay trustworthy.
A vacuum cleaner factory is a fast plastic moulding and assembly line where housings are moulded, motors are wound and fitted, filters are installed, and every finished cleaner is suction-tested before it ships. The line runs to a tight takt time, and compressed air touches each step, from the moulding machine that shapes the housing to the test rig that measures airflow.

The product must hold its suction for years in a dusty home, so a motor that was assembled with dirty air or a housing that was moulded with wet air becomes a warranty claim rather than a passing unit. Air quality at the moulding, motor and test stations is therefore a production issue, and buyers who audit the factory will ask about it directly.
Plastic Injection Moulding and Housing Forming
Vacuum cleaner housings are moulded from ABS and polypropylene on injection machines that use air for mould clamping, ejection and part handling. A pressure sag during ejection can leave a part stuck in the mould, and a stuck part stops the machine until an operator clears it by hand. Stable 7 bar air at the moulding line keeps every cycle on time.
Mould cooling and venting use air in quieter ways that still matter. Air jets clear plastic flash from mould vents, and a blocked vent leaves a burn mark on the next housing that shows up at final inspection. Keep the moulding branch filtered to 0.01 micron and dry it to a 3°C pressure dew point so oil never reaches a mould surface.
Colour changeovers are the worst moment of the shift for the air system. Several moulding machines purge and restart at once, and the surge coincides with the assembly line calling for more parts. A variable-speed drive compressor plus a 3,000 litre receiver absorbs that restart surge without a pressure dip.
- Hold 7 bar steady at the injection moulding line
- Filter moulding air to 0.01 micron with a 3°C dew point
- Size for colour-changeover restart surges
Motor Assembly, Winding and Balancing
Vacuum motors are wound, fitted and balanced in a dedicated bay, and the work is more precise than the rest of the plant suggests. Copper windings are placed by hand, bearings are pressed with air-assisted tools, and a press that over-travels because its air supply surged can damage a bearing before the motor is even tested. Regulate the motor benches to a steady 6.5 to 7 bar.
Motor balancing is the most air-sensitive job in the plant. The balancing machine spins the rotor at high speed while air-driven clamps hold it, and a vibration in the clamp from an unsteady air supply can look like an imbalance that is not really there. Regulate the balancing bay to a steady 7 bar and keep its air branch separate from the moulding hall.
Dust control is a constant concern in a motor bay that sits beside plastic moulding. Plastic fines and metal dust from the winding benches drift into the air, and dust drawn into the compressor intake scores the airend over time. Duct the intake to clean air outside and clean the cooler monthly.
- Regulate motor benches to a steady 6.5 to 7 bar
- Regulate the balancing bay on a separate 7 bar branch
- Duct the intake away from moulding and winding dust
Suction Testing, Filter Fitting and Final Inspection
Suction testing is the gate every vacuum cleaner must pass before shipping. The cleaner is run on a test rig while airflow and suction pressure are measured, and the air used to drive the test rigs must be stable, because a pressure dip during a test looks like a motor fault and wastes a test run. Keep the test branch filtered and regulated.
Filter fitting uses air in ways that are easy to overlook. HEPA filters are seated with air-assisted presses, and a filter seated at low pressure can leak dust past its edge in the customer's home. Regulate the filter benches to a steady 6 bar and check filter seating against a leak standard every week.
Final inspection and packing at the end of the line use air tools and handling equipment to move finished cleaners and their accessories. A slow handling station stretches the line takt time, and a scratched housing discovered at inspection means rework. Keep the inspection branch filtered and regulated, and drain the receiver and filter bowls every shift.
- Test suction with stable, regulated air from a dedicated branch
- Regulate filter benches to a steady 6 bar
- Drain receivers and filter bowls every shift
Buying from China: Sizing Sheet for Vacuum Cleaner Plants
Before requesting a quotation, gather four numbers: the injection moulding machine count and their ejection demand, the motor assembly tool count and peak flow, the suction-test bay air quality specification, and the distance from the compressor room to the furthest assembly bench. A supplier that quotes from the cleaner output alone will miss the moulding peak that actually sizes the system.
For most vacuum cleaner plants the practical range is a 37 to 75 kW variable-speed drive screw compressor at 7.5 or 8 bar, with a refrigerated dryer, 0.01 micron filtration, carbon adsorption and a 2,000 to 3,000 litre receiver. Larger plants with several moulding lines usually run a duty-plus-standby pair so maintenance never stops a suction test.
When comparing Chinese suppliers, ask for the full package price including dryer, filters, receiver and commissioning spares, and confirm the export packing, voltage and documentation for your country. Check the filter element life, the service interval and the availability of filters and airends through the supplier's export channel. QiAir, a Chinese screw compressor manufacturer and supplier, quotes the complete package so buyers compare real installed cost.
- Collect moulding, motor and test loads before quoting
- Budget 37 to 75 kW VSD plus dryer and carbon filtration
- Confirm spares, voltage and export packing in writing
Frequently asked questions
What pressure does a vacuum cleaner plant normally run?
Most run 7 to 8 bar at the header, with moulding lines at 7 bar, motor benches regulated to 6.5 to 7 bar, and filter benches held at a steady 6 bar.
Why does motor balancing need its own air branch?
A vibration in the balancing clamp from an unsteady air supply can look like an imbalance that is not really there. A separate regulated branch keeps balance measurements trustworthy.
Should moulding air share a line with motor assembly?
It can share the compressor room, but give motor balancing and assembly their own regulated branch, so moulding surges can never disturb a balance measurement.
How much air does a vacuum cleaner plant use?
Most plants run 5 to 12 m3/min on 37 to 90 kW compressors, with the moulding and ejection peaks deciding the size rather than the average assembly load.
Related reading
- Screw Air Compressor Maintenance Checklist from a China Manufacturer
- How to Size a Screw Compressor: Air Demand Calculation Before You Buy from China
QiAir is a Chinese manufacturer and supplier of screw air compressors. If you are sourcing a screw compressor from China — for a factory, a food plant, a construction site or a new production line — contact QiAir for a sized quotation, documented performance data and export support.