TL;DR — Direct answer: A refrigerator manufacturing plant typically runs 7 to 8 bar, 6 to 14 m3/min, on 45 to 110 kW rotary screw compressors, with a 3°C pressure dew point dryer and 0.01 micron filtration protecting sheet metal work, foam injection and refrigerant charging from moisture and oil. QiAir, a Chinese screw compressor manufacturer and supplier, sizes systems with dry, stable air so leak tests never give false readings.
A refrigerator factory is a mix of sheet metal work, chemical foaming and precision refrigeration, all running on one fast assembly line. Cabinets are formed and foamed, compressors are fitted, refrigerant is charged, and every finished unit is leak-tested before it ships. Compressed air touches each of those steps, and a failure anywhere stops a line that cannot afford to wait.

The product must hold its refrigerant charge for fifteen years in a kitchen, so a moisture event in the factory can become a warranty claim years later. Water inside a refrigerant circuit forms acid that eats the compressor from the inside, which is why the air used for purging and testing must be as dry as the circuit itself.
Sheet Metal Forming, Foaming and Cabinet Assembly
Refrigerator cabinets start as sheet steel, punched, bent and assembled on lines that use air for clamping, ejection and handling. Punch presses cycle hundreds of times per hour, and a pressure sag changes the clamping force enough to leave a misaligned panel that later shows up as a door that does not seal. Stable 7 bar air at the press line keeps every panel in place.
Foam injection is the most air-sensitive step on the cabinet line. Polyurethane foam is injected between the inner and outer walls, and the injection heads, mould clamps and metering pumps all run on compressed air. A pressure dip during injection leaves a void in the insulation that becomes a warm spot in the finished fridge.
Cabinet assembly benches run on dozens of small pneumatic tools, and their combined demand is spiky rather than steady, with peaks when several benches start a cabinet together. A variable-speed drive compressor follows those peaks smoothly, while a fixed-speed machine would cycle on and off and wear out its starter.
- Hold 7 bar steady at the press and foaming lines
- Regulate foam injection air to a steady 7 bar
- Use a VSD compressor for spiky assembly-bench loads
Refrigerant Charging, Brazing and Pipework
Refrigerant charging is the most tightly controlled job in a refrigerator plant. Copper pipes are brazed by hand, the circuit is evacuated and charged, and the air used for purging before charging must be dry enough that no moisture remains to form acid. A desiccant dryer giving minus 20°C dew point is the standard for the purging branch.
Brazing uses air for torches, clamps and handling fixtures, and a wet air line near a hot joint can throw moisture into the pipe before it is capped. Keep the brazing branch dried to a 3°C pressure dew point and filtered to 0.01 micron, and purge each circuit with dry air immediately after brazing.
Refrigerant safety rules shape the compressor room layout. The air compressor must never share an intake with a refrigerant storage area, and the charging bay needs ventilation that clears any accidental release quickly. Keep the intake ducted to clean outside air and fit a refrigerant detector in the charging bay.
- Purge circuits with desiccant-dried air to minus 20°C dew point
- Dry brazing air to a 3°C pressure dew point
- Site the intake away from refrigerant storage areas
Leak Testing, Final Inspection and Packing
Leak testing is the gate every refrigerator must pass before shipping. The circuit is pressurised with dry air or nitrogen and held while technicians watch for a pressure decay that signals a leak. Moisture inside the circuit changes the pressure reading and can mask a real leak, so test only with dry, oil-free air from a dedicated branch.
Final inspection uses air in quieter ways that still matter. Pneumatic test rigs check every door seal, hinge and control, and a slow cylinder during inspection looks like a product fault. Keep the inspection branch filtered and regulated, and log the dew point during every leak-test session.
Packing and handling at the end of the line use air hoists and lifting beams to move finished units that weigh over a hundred kilograms. A slow hoist stretches the line takt time, and a hoist that drops a unit because its air supply faltered is a scrapped refrigerator. Give the packing area its own receiver and drain it every shift.
- Test with dry, oil-free air from a dedicated branch
- Log the dew point during every leak-test session
- Fit a receiver near the packing and handling area
Buying from China: Sizing Sheet for Refrigerator Plants
Before requesting a quotation, gather four numbers: the press and foaming peak flow, the refrigerant charging and purging air demand and its dew point target, the leak-test bay air quality specification, and the distance from the compressor room to the furthest assembly bench. A supplier that quotes from the refrigerator output alone will miss the drying specification that actually decides the system.
For most refrigerator plants the practical range is a 45 to 90 kW variable-speed drive screw compressor at 7.5 or 8 bar, with a refrigerated dryer, a desiccant dryer for purging, 0.01 micron filtration and a 3,000 to 5,000 litre receiver. Larger plants with several assembly lines usually run a duty-plus-standby pair so maintenance never stops a leak test.
When comparing Chinese suppliers, ask for the full package price including both dryers, filters, receiver and commissioning spares, and confirm the export packing, voltage and documentation for your country. Check the desiccant dryer running cost, the service interval and the availability of filters and airends through the supplier's export channel. QiAir, a Chinese screw compressor manufacturer and supplier, quotes the complete package so buyers compare real installed cost.
- Collect foaming, charging and test loads before quoting
- Budget 45 to 90 kW VSD plus two-stage drying
- Confirm desiccant running cost, spares and export packing in writing
Frequently asked questions
What pressure does a refrigerator plant normally run?
Most run 7 to 8 bar at the header, regulated to 6 bar at inspection benches and 7 bar at foaming and brazing stations, so clamping and test readings stay consistent.
Why does refrigerant purging need a desiccant dryer?
A refrigerated dryer at a 3°C pressure dew point leaves enough moisture to form acid inside a refrigerant circuit. Desiccant drying to minus 20°C keeps the circuit dry before charging.
Can moisture cause a false leak-test result?
Yes. Moisture inside a circuit changes the pressure reading during a hold test and can mask a real leak, while oil coats leak detectors. Test only with dry, oil-free air.
Should charging air share a line with sheet metal tools?
No. Give refrigerant charging and purging their own dryer and filtration branch, so metal dust and tool oil can never reach a refrigerant circuit.